Microscopes
Every slide, read the same way.
A slide asks a question, and the answer can sit in a few cells anywhere on the glass. A pathologist looks for them by eye, one field at a time.
A pathologist’s time is the scarce thing in any lab. We are building a benchtop microscope that reads every slide the same way, every time, so the hours go to judgment, not to searching the glass.
01The aperture
The read begins with the light.
The light meets an opening before it meets a lens. Under the slide, a plate narrows or widens the cone that reaches the tissue. A narrow opening gives more contrast and a deeper band in focus. A wide one gives more light and finer detail.
One opening serves every slide, so when two sections sit side by side, the light is not the difference.
02The objective
Sharp across the field.
The objective gathers the light that has come through the tissue. A train of lens elements bends it in steps, each correcting the last, so the image is as sharp at the edge of the field as at the center.
We chose the objective rather than grind our own, and built the instrument around it: its seat, the focus drive and the distance to the sensor.
03The stage
A scan you can repeat.
The stage carries the slide under the objective in steps smaller than a cell. Crossed-roller rails hold each axis true, and a lead screw turns the motor’s steps into moves the stage can repeat.
A scan runs row by row across the glass until the whole section has passed under the lens, the same path on each slide, so no corner is missed.
04The sensor
A whole slide becomes data.
A sensor at the end of the light’s path takes the image tile by tile, and the tiles are laid edge to edge into one picture of the section. The focus drive follows the glass as it rises and falls.
Glass sits in a drawer and its stain fades. The image lasts, so a lab can set a section from years ago beside a new one.
05The read
The pathologist decides.
A pathologist gets the image on a screen, all of it, and can open any part at full magnification. In a pilot, the model would flag regions of the section for a person to look at first.
The flags are suggestions and nothing else. The pathologist reads the whole section, decides what each region is and writes the finding. The model makes no diagnosis.
For research and laboratory use. Not for diagnostic use.
Outcome
Built in one house.
We build the light’s path, from the condenser to the sensor, and the AI in one house, so each part is made for the image a model would learn from, and the pathologist keeps the decision.
A pilot begins with a lab’s own slides and ends with a model the lab can judge for itself, flag by flag, against its own pathologists’ reads.